Branch Circuit Diagram

Branch circuit diagram
Branch wiring design refers to the circuit design of the circuits that supply electricity to different areas in a home. Branch wiring originates from the service distribution panel that has two hot bus bars and a neutral bus bar.
What is a branch circuit used for?
A branch circuit is the means to carry electric power from the final overcurrent device protecting the circuit to the outlets and equipment in residential, commercial, and industrial locations. NEC Article 210 covers general requirements for branch circuits.
What are the 4 types of branch circuits?
NEC Article 100 also tells us that there are four (4) types of branch circuits:
- Branch Circuit: appliances.
- Branch Circuit: general purpose.
- Branch Circuit: individual.
- Branch Circuit: multi wires.
What is the NEC definition branch circuit?
The first step in eliminating this confusion is to understand that the NEC defines a branch circuit as “the conductors between the branch circuit final overcurrent device protecting the circuit and the outlets” (such as receptacles or lights) [Art.
What is a 3 wire branch circuit?
A typical 3-wire circuit is actually two otherwise-separate parallel circuits with a common conductor. If the grounded (neutral) conductor is accidentally opened, the circuit changes from two separate parallel 120 V circuits to one 240 V series circuit.
Can 2 hot wires share a neutral?
One neutral may not have two “hot” wires from the same phase. It is good practice to use four (4) pole Circuit breakers (as opposed to the standard three pole) where the fourth pole is the neutral phase, and is hence protected against over current on the neutral conductor.
Is a home run a branch circuit?
It's the part of the branch circuit that goes from the OCPD to the first junction point, that could be at a receptacle box, a switch, or a junction box. We typically run EMT homeruns from the panel to a point in the ceiling where there would be a junction box.
How long can a branch circuit be?
There is no restriction on the length of track that can be supplied from a 20-ampere, 120-volt branch circuit. Where it is known that 40 feet of track will not be loaded to more than 16 amperes (track lighting in a museum is considered to be a continuous load), a single 20-ampere branch circuit is acceptable.
How many branch circuits are required in a home?
Typically, 120-volt branch circuits supply power to standard fixtures and outlets and 240-volt circuits power major appliances. There are four types of branch circuits in your home.
What is a single branch circuit?
An individual branch circuit is a circuit that supplies only one piece of utilization equipment (e.g., one range, one space heater, one motor). See 210.23 regarding permissible loads for branch circuits. An individual branch circuit supplies only one single receptacle for the connection of a single attachment plug.
What is a 20 amp branch circuit?
210-23(a) 15- and 20-Ampere Branch Circuits A 15- or 20-ampere branch circuit can supply lighting units, other utilization equipment, or a combination of both. The rating of any one cord-and-plug-connected piece of utilization equipment must not exceed 80 percent of the branch-circuit ampere rating.
What is the difference between feeder and branch circuit?
A feeder is the circuit conductors between the service equipment, the source of a separately derived system, or other power source and the final branch-circuit overcurrent device. Conductors past the final OCPD protecting the circuit and the outlet are branch-circuit conductors [Art.
Can I use one ground wire for multiple circuits?
The code requires each branch circuit to have an equipment ground (either a wire, or conduit, or cable tray as in 250.120A), they can be shared when they are in the same raceway. If all the 20A circuits are in one raceway then you just need one ground.
How deep does a branch circuit need to be?
A: The wiring method must be buried at least 12 inches deep. B: A lesser depth shall be permitted where specified in the installation instructions of a listed low voltage lighting system.
Does a dining room need a dedicated circuit?
Any wall section wider than 2 feet must have a receptacle. Dining rooms usually require a separate 20-amp circuit for one outlet used for a microwave, entertainment center, or window air conditioner.
What is an example of a branch circuit?
A branch circuit is part of the electrical system that originates at the main service panel and feeds electricity throughout the structure. There are 120-volt branch circuits that supply power to standard outlets and fixtures, along with 240-volt circuits that power major appliances.
Can a dedicated circuit share a neutral?
If the neutral is shared then it is not dedicated to the circuit that requires it as dedicated. Whereas a separate circuit does not imply to me that the neutral cannot be shared.
Are multi wire branch circuits legal?
The National Electrical Code permits multiwire branch circuits, but adds requirements to make them safer. Section 210.4(B) states that in the panelboard where the branch circuit originates, all ungrounded conductors must be provided with a means to disconnect them simultaneously.
How many circuits can be on neutral?
You can only have one neutral per circuit in a single phase system, it is a current carrying conductor.
How many amps does a neutral carry?
By substituting each phase current into the Neutral Current formula below, the neutral current is 2.22 Amps.